Product ID:: |
1SDA056144R1 |
Product Series: |
ABB SACE Emax E3N |
Product Type: |
Low Voltage Air Circuit Breaker |
Rated Current: |
3200 A |
Number Of Poles: |
3P |
Installation Type: |
Fixed Version |
Terminal Arrangement: |
Rear Horizontal Terminals |
Trip Unit: |
PR121/P-LI Electronic Trip Unit |
Protection Functions: |
Long Time And Instantaneous Overcurrent Protection |
Rated Operational Voltage: |
690 VAC |
Rated Insulation Voltage: |
1000 VAC |
Rated Impulse Withstand Voltage: |
12 KV |
Breaking Capacity: |
65 KA |
Frequency: |
50 To 60 Hz |
Auxiliary Contacts: |
4 Auxiliary Contacts Included |
Mechanical Durability: |
20000 Operating Cycles |
Product ID:: |
1SDA056144R1 |
Product Series: |
ABB SACE Emax E3N |
Product Type: |
Low Voltage Air Circuit Breaker |
Rated Current: |
3200 A |
Number Of Poles: |
3P |
Installation Type: |
Fixed Version |
Terminal Arrangement: |
Rear Horizontal Terminals |
Trip Unit: |
PR121/P-LI Electronic Trip Unit |
Protection Functions: |
Long Time And Instantaneous Overcurrent Protection |
Rated Operational Voltage: |
690 VAC |
Rated Insulation Voltage: |
1000 VAC |
Rated Impulse Withstand Voltage: |
12 KV |
Breaking Capacity: |
65 KA |
Frequency: |
50 To 60 Hz |
Auxiliary Contacts: |
4 Auxiliary Contacts Included |
Mechanical Durability: |
20000 Operating Cycles |
The ABB E3N 3200 PR121/P-LI In=3200A 3P F HR is a fixed three-pole air circuit breaker for low-voltage power distribution systems with a rated current of 3200 A.
This configuration uses rear horizontal terminals, making it suitable for switchboard layouts where busbar connections are routed from the rear of the breaker. The PR121/P-LI electronic trip unit provides long-time overload protection and instantaneous short-circuit protection for feeder, incomer, and distribution applications.
Unlike a molded-case circuit breaker, this E3N air circuit breaker is intended for higher-current switchgear assemblies where maintainability, coordination, and breaker status monitoring are important. The supplied auxiliary contacts and open-closed position indication support integration with panel control and monitoring circuits.
This page should describe only the fixed 3P rear-horizontal version with PR121/P-LI protection. Do not mix it with withdrawable versions, four-pole versions, PR122 or PR123 trip units, or E3H and E3S variants.
3200 A rated current
Three-pole fixed air circuit breaker
Rear horizontal terminal arrangement
PR121/P-LI electronic trip unit
Long-time overload protection
Instantaneous short-circuit protection
690 VAC rated operational voltage
1000 VAC rated insulation voltage
12 kV impulse withstand voltage
65 kA breaking capacity
Four auxiliary contacts included
Open and closed breaker position indication
Main incomer panels
Large feeder circuits
Low-voltage switchboards
Industrial distribution boards
Motor control center incomers
Commercial building power systems
Generator distribution panels
Plant electrical infrastructure
Install the breaker in a compatible low-voltage switchboard using the correct fixed-frame mounting arrangement.
Confirm the rear horizontal busbar layout, phase spacing, rated current requirement, and PR121/P-LI protection settings before replacement.
The protection settings must be coordinated with the upstream and downstream protective devices by a qualified electrical engineer.
Do not describe this model as a molded-case breaker, a withdrawable breaker, or a four-pole breaker.
Q
Is this a fixed or withdrawable breaker
A
It is a fixed air circuit breaker
Q
How many poles does this breaker have
A
It has three poles
Q
What does PR121/P-LI mean
A
It is an electronic trip unit with long-time overload protection and instantaneous short-circuit protection
Q
What is the rated current
A
The rated current is 3200 A
Q
What does HR mean
A
HR indicates rear horizontal terminals