Product Details
Place of Origin: USA
Brand Name: Allen Bradley
Certification: CE UL cURus E360421
Model Number: 100-C23KF01
Payment & Shipping Terms
Minimum Order Quantity: 1 PCS
Price: 50-150 USD/PCS
Packaging Details: Carton packaging
Delivery Time: 3-7 working days
Payment Terms: D/A, D/P, T/T, Western Union
Supply Ability: 100 PCS/ 4 weeks
Product Name: |
Contactor |
Condition: |
New And Original |
Market: |
Worldwide Market |
Shipping Term: |
UPS/DHL/FEDEX/TNT/EMS |
Warranty: |
One-year |
Quality: |
100% Goog Quality |
Color: |
White |
Product Name: |
Contactor |
Condition: |
New And Original |
Market: |
Worldwide Market |
Shipping Term: |
UPS/DHL/FEDEX/TNT/EMS |
Warranty: |
One-year |
Quality: |
100% Goog Quality |
Color: |
White |
In industrial safety systems where positive circuit interruption is non-negotiable, the Allen-Bradley 100-C23KF01 stands as a purpose-engineered solution within Rockwell Automation's Bulletin 100-C series. Featuring a specialized 0 N.O. / 1 N.C. auxiliary configuration and UL-certified 230V 50/60Hz coil, this contactor delivers failsafe performance for emergency stops, safety gate interlocks, and critical process shutdowns. Designed for North American markets requiring uncompromising compliance with NFPA 79 and ANSI B11.19, the 100-C23KF01 combines robust construction with diagnostic-ready safety features for automotive, packaging, and heavy machinery applications.
1. Fail-Safe Auxiliary Architecture
Dedicated N.C. (Normally Closed) Contact: Opens immediately upon coil energization, providing hardwired confirmation of circuit de-energization for SIL 3 applications.
0 N.O. Design: Eliminates risk of accidental circuit closure - critical for OSHA-compliant lockout/tagout (LOTO) procedures.
2. Position-Optimized Terminal System
Terminal Position 2 Marking: Pre-wired integration with safety relays like Allen-Bradley 440R-S12R2 without panel reconfiguration.
Line-Side Screw Terminals: Tool-free verification points for voltage testing during maintenance.
3. Universal Coil Technology
230V 50/60Hz TC-851 Coil: ±15% voltage tolerance handles grid fluctuations in aging industrial facilities.
Surge-Protected Design: Withstands 2.5kV transients without external suppressors.
*Table: 100-C23KF01 Safety Integrity Parameters*
Parameter | Specification | Industry Standard | Safety Margin |
---|---|---|---|
De-Energization Time | ≤35ms @ 230VAC | ≤50ms (ANSI B11.19) | 30% faster |
Contact Force (N.C.) | 4.5N minimum | 3.0N (UL 60947-4-1) | 50% higher |
Dielectric Strength | 2500V AC between coil/contacts | 1500V (minimum requirement) | 67% excess capacity |
Fault Current Withstand | 10kA/100ms | 5kA/50ms (typical) | 2× duration capability |
Mechanical Life (N.C.) | 500,000 operations | 100,000 (safety relay average) | 5× lifespan |
Coil Drop-Out Voltage | 20-60% of nominal | 10-75% (IEC 60947) | Optimized fail-safe range |
Environmental Sealing | IP40 (terminal protection) | IP20 (standard) | Dust-protected contacts |
1. Robotic Cell Emergency Stops
Achieves Category 4 PL e per ISO 13849
2. Hydraulic Power Unit Isolation
Prevents unexpected restart after maintenance via N.C.-verified de-energization
Complies with NFPA 79 7.2.2.2 isolation requirements
3. Conveyor Safety Interlocks
N.C. contact opens when guard removed, halting motion within 50ms
4. Burner Management Systems
Provides SIL 2-certified fuel valve shutdown (ANSI/ISA 84.00.01)
Safety Circuit Implementation:
Critical Commissioning Steps:
Contact Force Verification: 4.5N min with spring gauge (annual test)
De-Energization Timing: Validate ≤35ms with oscilloscope
Dielectric Testing: 1800V AC for 1s between coil/main circuit
Functional Safety Validation:
500 consecutive operations @ 110% voltage
500 operations @ 85% voltage
Predictive Maintenance Schedule:
Indicator | Tool | Threshold | Frequency |
---|---|---|---|
N.C. Contact Resistance | Micro-ohmmeter | >100mΩ | Quarterly |
Contact Gap | Feeler gauge | <0.2mm | 50k operations |
Coil Insulation | 1000V megger | <10MΩ | Annually |
Safety Partner Compatibility:
GuardMaster 440C-CR30 safety relays
Kinetix 5700 safe torque off (STO)
FactoryTalk View SE safety HMI acknowledgment
Digital Validation Tools:
Emulate3D safety sequence simulation
Studio 5000 Safety I/O validation
Lifecycle Management:
Spare coil TC-851 stocked at 100% US distributors
Field replacement time <7 minutes
Sector | Application | Safety Outcome |
---|---|---|
Automotive Press | 800-ton Stamping Machine E-Stop | Zero unintended restarts (3 years) |
Pharmaceutical | Sterilizer Door Interlock | Eliminated bio-contamination incidents |
Material Handling | Robotic Palletizer Gate | Reduced LOTO violations by 92% |
Energy | Turbine Lube Oil Pump | Prevented $1.2M fire risk (failed start) |
The Allen-Bradley 100-C23KF01 redefines safety circuit reliability through its dedicated 0 N.O./1 N.C. architecture and position-optimized termination. As the only UL-certified contactor in its class with integrated safety diagnostics, it eliminates 73% of components in Category 4 safety circuits while providing auditable de-energization proof. For engineers designing automotive production cells, food processing lines, or high-energy machinery, this contactor delivers more than switching - it provides legally defensible safety compliance with 50% faster installation and 80% lower validation costs. Backed by Rockwell Automation's SafetyMaturity program and 24/7 technical support, the 100-C23KF01 establishes a new benchmark in risk reduction for industrial control systems.
Tags: