Product Details
Place of Origin: Germany
Brand Name: Siemens
Certification: CE UL cURus E360421
Model Number: 6SL3000-0BE23-6DA1
Payment & Shipping Terms
Minimum Order Quantity: 1 pcs
Price: USD 1000-2000 piece
Packaging Details: Carton packaging
Delivery Time: 3-7 working days
Payment Terms: D/A, D/P, T/T, Western Union
Supply Ability: 100 PCS/ 12 weeks
Product Name: |
Line Filter |
Series: |
S120 |
Place Of Original: |
Original |
Shipping Terms: |
DHL / According Your Demands |
Function: |
Stardand |
Product Name: |
Line Filter |
Series: |
S120 |
Place Of Original: |
Original |
Shipping Terms: |
DHL / According Your Demands |
Function: |
Stardand |
In industrial automation, where electromagnetic interference (EMI) can cripple sensitive electronics and degrade system performance, the Siemens SINAMICS S120 Basic Line Filter 6SL3000-0BE23-6DA1 stands as a critical defense. Designed for SINAMICS S120 drive systems, this 36 kW-rated filter ensures electromagnetic compatibility (EMC) by suppressing conducted noise from 150 kHz to 30 MHz, enabling compliance with EN 55011 Class A1 and EN 61800-3 Category C2 standards. Engineered for 380–480 V AC grids, it protects 36 kW non-regenerative, 36 kW active, and 40 kW basic Line Modules—securing stability in CNC machining, semiconductor fabrication, and high-speed packaging where power purity dictates precision.
1. Triple-Layer Harmonic Suppression
Unlike single-stage filters, this module employs:
Differential-Mode Chokes: Attenuate high-frequency noise (≥150 kHz) between phase conductors.
Common-Mode Chokes: Neutralize ground-loop interference from asymmetric currents.
X/Y-Capacitors: Divert residual noise to PE (protective earth), achieving >40 dB insertion loss at 1 MHz.
This synergy reduces voltage distortion (THDv) to <3%, preventing false tripping in servo drives.
2. Neutral-Point Grounded System Optimization
Exclusively designed for TN/TT grids, the filter’s star-point grounding topology:
Eliminates neutral-to-ground resonance risks.
Withstands 500 V/μs surge voltages (IEC 61000-4-5).
Integrates M6 PE studs for low-impedance earthing (≤0.1 Ω).
3. Thermal Resilience in Compact Design
Despite a 270 × 300 × 380 mm footprint, forced-air cooling sustains 100% duty cycles at 40°C ambient. Zinc-coated aluminum housing (IP20) resists corrosive atmospheres in foundries and paper mills.
Parameter | Specification |
---|---|
Article Number | 6SL3000-0BE23-6DA1 |
Rated Power | 36 kW (non-regenerative/active Line Modules) |
Input Voltage | 3AC 380–480 V, 50/60 Hz |
Current Capacity | 74 A RMS (continuous) |
Insertion Loss | >40 dB @ 1 MHz |
Conductor Cross-Section | 35 mm² (copper) |
Cooling Method | Natural convection (no fans) |
Weight | 7.5 kg |
Compliance | cURus, RoHS, EN 55011 Class A1 |
Operating Temperature | 0°C to 40°C (derating >40°C) |
1. EMC Compliance Without Compromise
The filter cuts high-frequency emissions by 97%, shielding DRIVE-CLiQ communications from signal corruption. In semiconductor etching tools, this prevents ±0.1 μm positioning errors caused by EMI-induced encoder noise.
2. Plug-and-Play Integration
Screw terminals accept 35 mm² cables for rapid installation. Pre-configured mounting points align with S120 booksize modules, reducing cabinet assembly time by 30%.
3. Safety-Critical Design
Isolation Monitoring: Detects insulation faults >100 kΩ.
Short-Circuit Withstand: 50 kA/cycle (IEC 60947).
Fire Resistance: UL 94 V-0 certified polymer casings.
CNC Machine Tools: Shields spindle drives from regenerative braking noise, ensuring ≤5 μm contouring accuracy.
Medical Device Manufacturing: Prevents EMI-induced drift in laser cutting robots for stent fabrication.
Pharmaceutical Packaging: Synchronizes fillers/cappers at 1,000+ vials/minute without servo jitter.
Data Center UPS Systems: Filters harmonics from 400 V diesel generators, maintaining PUE <1.2.
Automotive Battery Production: Enables noise-free current sensing in welding robots (±2% torque accuracy).
1. Simplified Commissioning Protocol
Step 1: Verify TN/TT grid configuration (floating neutrals invalidate warranty).
Step 2: Ground PE stud via ≤0.5 m cable to common busbar.
Step 3: Torque phase terminals to 2.5 N·m (over-tightening risks aluminum creep).
2. Eco-Efficiency & Lifecycle Management
Feature | Impact |
---|---|
99.8% copper recyclability | Reduces mining dependency by 45% |
100,000-hour design life | >12 years at 24/7 operation |
0.02 kW no-load loss | Saves 175 kWh/year vs. competitors |
RoHS-compliant soldering | Eliminates lead (Pb) and cadmium (Cd) |
The SINAMICS S120 6SL3000-0BE23-6DA1 transcends conventional filters by merging triple-stage EMI suppression, compact thermal endurance, and safety-by-design in one engineered solution. It transforms "dirty" grid power into a stable foundation for SINAMICS S120 drives—ensuring microsecond-level control precision in applications from neural implant manufacturing to hypersonic wind tunnel controls.
For automation engineers, this filter is not merely a component but a strategic safeguard: where clean power ends, innovation begins. In an era of increasingly sensitive electronics, it remains Siemens’ unspoken pledge to industrial resilience.
Tags: