gtag('config', 'G-GQCVZH2L3Z', {cookie_flags: "SameSite=None;Secure"});
Dengfeng (Zhaoqing) Trading Co., Ltd
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
Home /

Products

TM5SMM6D2L | Schneider Electric | The High-Density DC Actuator Command Center for Demanding Automation

Product Details

Place of Origin: France

Brand Name: Schneider

Certification: CE UL cURus E360421

Model Number: TM5SMM6D2L

Payment & Shipping Terms

Minimum Order Quantity: 1 piece

Price: USD 100-200 piece

Packaging Details: 10*6*2.5 CM

Delivery Time: 3-7 working days

Payment Terms: D/A, D/P, T/T, Western Union

Supply Ability: 10 piece 5 days

Get Best Price
Contact Now
Specifications
Highlight:
Condition:
New
Product Name:
IO Module
Application:
Industral Automation
Shipping Terms:
DHL, FedEx, UPS‌
Temperature:
0-55°C
Condition:
New
Product Name:
IO Module
Application:
Industral Automation
Shipping Terms:
DHL, FedEx, UPS‌
Temperature:
0-55°C
Description
TM5SMM6D2L | Schneider Electric | The High-Density DC Actuator Command Center for Demanding Automation

In the dynamic environment of modern industrial automation, control systems frequently encounter the need to process both simple on/off signals and precise analog commands within the same localized area. Utilizing separate, dedicated modules for digital and analog functions can consume valuable cabinet space and increase system complexity. The Schneider Electric Modicon TM5SMM6D2L directly addresses this challenge as a highly versatile mixed I/O module for the Modicon TM5 system. By ingeniously combining six digital inputs with two analog outputs in a single, standard TM5 form factor, this module provides a compact and efficient solution for machine segments that require both discrete sensing and continuous variable control, thereby streamlining hardware design and simplifying integration.

The TM5SMM6D2L is engineered for applications where a cluster of sensor signals must be interpreted alongside the generation of proportional control signals. The six digital inputs are ideal for monitoring the state of devices like push buttons, limit switches, or presence sensors. Simultaneously, the two analog outputs can be tasked with commanding devices such as proportional valves, variable frequency drive speed references, or analog display units. This integrated capability makes the module exceptionally suitable for sub-systems like indexing tables, dosing units, tension control zones, or small conveyor sections where both logic and fine-tuned regulation are essential. It effectively reduces the module count, saving space, reducing wiring, and lowering the total component cost for such applications.

Technical Specifications and Functional Details:

 
 
Feature Specification for TM5SMM6D2L
Module Type Mixed Signal I/O Module (Digital Input / Analog Output)
Module Reference TM5SMM6D2L
Digital Inputs 6 points, 24V DC (Sink/Source configurable)
Analog Outputs 2 channels, Voltage or Current output configurable
Analog Output Range Typically 0-10V or 0/4-20mA, software selectable per channel
Analog Resolution High-resolution (e.g., 12-bit or 16-bit, refer to datasheet) for precise command generation.
Electrical Connection Removable screw terminal blocks for all field connections.
Isolation Separation between digital input circuits, analog outputs, and the TM5 system bus.
Configuration Fully programmable via EcoStruxure Machine Expert (input filtering, output type, scaling).
System Integration Plugs directly into the TM5 DIN-rail bus; supports TM5 hot-swap functionality.
Key Application Role Localized control of subsystems requiring both discrete feedback and continuous actuation.

The intelligence of the TM5SMM6D2L lies in its software-configurable flexibility. Each of the six digital inputs can have its filter time individually adjusted to ensure noise immunity and reliable state detection. The two analog outputs are independently configurable; an engineer can set one channel to a 0-10V signal for a valve controller and the other to a 4-20 mA signal for a drive, all within the same module. This high degree of customization allows the module to be perfectly tailored to its specific task without hardware changes. Its integration into the unified TM5 architecture means all parameters and diagnostic data are accessible through the central controller, providing a cohesive and maintainable system view.

Compared to using a combination of a discrete input module and a separate analog output module, the TM5SMM6D2L offers a more elegant and consolidated solution. It occupies only one slot on the TM5 bus, conserves addressing space, and simplifies the electrical bill of materials. This module exemplifies the TM5 philosophy of application-optimized design, providing a right-sized solution for common mixed-signal requirements without over-engineering.

In summary, the Modicon TM5SMM6D2L mixed I/O module is a cornerstone for efficient and intelligent machine design. It empowers system integrators to reduce hardware sprawl, lower costs, and achieve cleaner control architectures for subsystems that blend digital and analog worlds. By delivering integrated signal management in a robust and flexible package, it enhances the scalability and performance of automated equipment built on the future-proof Modicon TM5 platform.