Product Details
Place of Origin: Austria
Brand Name: B&R
Certification: CE
Model Number: 80VD100PD.C188-01
Payment & Shipping Terms
Minimum Order Quantity: 1 pcs
Packaging Details: Carton packaging
Delivery Time: 3-7 working days
Payment Terms: D/A, D/P, T/T, Western Union
Product Type: |
Two Axis Servo Inverter Module |
Product Series: |
ACOPOSmicro |
Communication Interface: |
X2X POWERLINK |
Motor Connections: |
2 Servo Motor Connections |
Motor Feedback Interface: |
2 X LinMot Interface |
Power Supply: |
24 To 64 VDC ±25% |
Continuous Current: |
8 A |
Digital Inputs: |
2 X 24 VDC Sink Inputs |
Trigger Input Function: |
Supported |
Digital Output: |
1 X 24 VDC 1 A Output |
Motor Holding Brake Connection: |
Supported |
Enable Input: |
Supported |
Axis Configuration: |
Two Axis |
Installation Type: |
Control Cabinet Installation |
Terminal Blocks: |
Order Separately |
Product Type: |
Two Axis Servo Inverter Module |
Product Series: |
ACOPOSmicro |
Communication Interface: |
X2X POWERLINK |
Motor Connections: |
2 Servo Motor Connections |
Motor Feedback Interface: |
2 X LinMot Interface |
Power Supply: |
24 To 64 VDC ±25% |
Continuous Current: |
8 A |
Digital Inputs: |
2 X 24 VDC Sink Inputs |
Trigger Input Function: |
Supported |
Digital Output: |
1 X 24 VDC 1 A Output |
Motor Holding Brake Connection: |
Supported |
Enable Input: |
Supported |
Axis Configuration: |
Two Axis |
Installation Type: |
Control Cabinet Installation |
Terminal Blocks: |
Order Separately |
The B&R 80VD100PD.C188-01 is an ACOPOSmicro two-axis servo inverter module designed for compact motion systems using LinMot motor interfaces.
This module controls two servo axes from one cabinet-mounted unit. It communicates through X2X POWERLINK and operates from a 24 to 64 VDC supply, making it suitable for compact machine architectures with distributed motion hardware.
The C188 configuration includes two LinMot interfaces. This is the key model-specific feature and should be retained in the title, product description, and technical parameters. It is not a general-purpose encoder module and should not be described as an FPGA-based controller.
Two 24 VDC digital inputs can be used as trigger inputs, while the 24 VDC digital output can support machine-side status or switching functions. The module also provides holding-brake connection and enable input for connected motion axes.
This product is a servo inverter module only. It should not be described as a PLC, industrial computer, stepper motor controller, power supply module, field-programmable metamaterial device, or standalone I/O module.
Two-axis servo inverter module
X2X POWERLINK communication
Two LinMot motor interfaces
24 to 64 VDC power supply range
8 A continuous current
Two 24 VDC trigger-capable inputs
One 24 VDC 1 A digital output
Holding-brake connection
Enable input
Compact ACOPOSmicro format
Control cabinet installation
Terminal blocks ordered separately
Linear motion modules
Compact packaging equipment
Pick-and-place systems
Assembly machines
Servo feeders
Material handling equipment
Labeling machinery
Compact automation retrofits
Multi-axis motion cabinets
Confirm that the original module is 80VD100PD.C188-01 and that the connected motor system uses LinMot interfaces.
Verify the X2X POWERLINK network configuration, 24 to 64 VDC supply range, motor wiring, brake wiring, enable circuit, and digital I/O assignment before commissioning.
Terminal blocks are ordered separately and should match the original machine installation.
Install the module inside a properly grounded electrical cabinet and follow the original wiring and shielding arrangement.
Q
Is 80VD100PD.C188-01 a PLC controller
A
No it is a two-axis ACOPOSmicro servo inverter module
Q
How many servo motors can this module control
A
It supports two servo motor connections
Q
What motor interface does this version use
A
It includes two LinMot interfaces
Q
What communication interface does it use
A
It uses X2X POWERLINK communication
Q
What supply voltage is required
A
The module operates from 24 to 64 VDC with ±25 percent tolerance
Q
Are terminal blocks included
A
No terminal blocks must be ordered separately
Tags: