Product Details
Place of Origin: GERMANY
Model Number: HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW
Payment & Shipping Terms
Material Number: |
R911325247 |
Product Family: |
IndraDrive Cs HCS01 |
Product Type: |
Single-axis Compact Converter With Integrated Control Section |
Maximum Current: |
18 A |
Continuous Current: |
7 A |
Mains Input: |
3 AC 200 To 500 V, 50 To 60 Hz |
Control Section Class: |
BASIC |
Communication: |
ET MultiEthernet |
Encoder Interface: |
EC Multi-encoder Interface |
Safety Configuration: |
NN - Not Equipped |
Second Optional Interface: |
NN - Not Equipped |
Cooling: |
Internal Air Cooling With Integrated Blower |
Protection Rating: |
IP20 |
Reference Power Without Choke: |
1.7 KW Continuous, 4.8 KW Maximum |
Nominal Dimensions: |
70 X 220 X 268 Mm, Width X Height X Depth |
Reference Weight: |
Approximately 2.10 Kg, Revision Dependent |
Firmware: |
FW Placeholder - Firmware Must Be Selected Separately |
Material Number: |
R911325247 |
Product Family: |
IndraDrive Cs HCS01 |
Product Type: |
Single-axis Compact Converter With Integrated Control Section |
Maximum Current: |
18 A |
Continuous Current: |
7 A |
Mains Input: |
3 AC 200 To 500 V, 50 To 60 Hz |
Control Section Class: |
BASIC |
Communication: |
ET MultiEthernet |
Encoder Interface: |
EC Multi-encoder Interface |
Safety Configuration: |
NN - Not Equipped |
Second Optional Interface: |
NN - Not Equipped |
Cooling: |
Internal Air Cooling With Integrated Blower |
Protection Rating: |
IP20 |
Reference Power Without Choke: |
1.7 KW Continuous, 4.8 KW Maximum |
Nominal Dimensions: |
70 X 220 X 268 Mm, Width X Height X Depth |
Reference Weight: |
Approximately 2.10 Kg, Revision Dependent |
Firmware: |
FW Placeholder - Firmware Must Be Selected Separately |
The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is the general-purpose 18 A BASIC configuration in the compact HCS01 range. The power stage and control electronics are integrated in one drive, while ET MultiEthernet and EC multi-encoder hardware support flexible connection to the surrounding automation system and motor feedback.
Unlike the L4 and S4 versions, this order code has NN in the safety position and therefore must not be marketed as containing a drive-integrated safety option. It is best positioned as an exact spare for machines already using the same suffix, with the firmware, motor parameters and network protocol confirmed from the original project or nameplate data.
· 18 A maximum-current class with 7 A continuous-current reference
· BASIC integrated control section for economical single-axis applications
· ET MultiEthernet communication hardware
· EC multi-encoder interface for supported feedback systems
· No drive-integrated safety option in this exact NN configuration
· Compact IP20 housing with internal blower cooling
· General automation axes
· Conveyor and indexing systems
· Handling equipment
· Exact replacement for R911325247 installations
Match the entire model string, including the three NN option fields. An L4, S4 or other safety-equipped drive may have different wiring, commissioning and approval requirements even when the current class is also W0018.
Q1 Does this exact model include STO or Safe Motion?
No drive-integrated safety option is identified in this order code. The safety field is NN. Use the machine's external safety architecture or select the exact specified safety variant.
Q2 Which communication interface is built in?
The ET code identifies MultiEthernet hardware. Confirm the protocol selected by the firmware and the original machine project.
Q3 Is R911325247 the same as every HCS01 W0018 drive?
No. R911325247 maps to this exact BASIC, ET, EC and NN option combination. Other W0018 material numbers can differ in safety or optional interfaces.
Q4 Can the existing firmware be copied from the removed drive?
Parameter and firmware transfer may be possible in a controlled service process, but version compatibility and machine backups must be checked before replacement.
Q5 What is required for cabinet installation?
Provide suitable IP20 cabinet protection, grounding, ventilation clearance and clean cooling air. Follow the applicable project planning manual.
Q6 Why should the full suffix be included in the inquiry?
The suffix identifies control performance, communication, encoder and safety hardware. Supplying only HCS01.1E-W0018 can lead to an incompatible quotation.