Verification: dd9dbffd7e34a82b
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
english
Quote
Products
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
Home /

Products

HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW 18A Ethernet Drive

Product Details

Place of Origin: GERMANY

Model Number: HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW

Payment & Shipping Terms

Get Best Price
Contact Now
Specifications
Highlight:
Material Number:
R911325247
Product Family:
IndraDrive Cs HCS01
Product Type:
Single-axis Compact Converter With Integrated Control Section
Maximum Current:
18 A
Continuous Current:
7 A
Mains Input:
3 AC 200 To 500 V, 50 To 60 Hz
Control Section Class:
BASIC
Communication:
ET MultiEthernet
Encoder Interface:
EC Multi-encoder Interface
Safety Configuration:
NN - Not Equipped
Second Optional Interface:
NN - Not Equipped
Cooling:
Internal Air Cooling With Integrated Blower
Protection Rating:
IP20
Reference Power Without Choke:
1.7 KW Continuous, 4.8 KW Maximum
Nominal Dimensions:
70 X 220 X 268 Mm, Width X Height X Depth
Reference Weight:
Approximately 2.10 Kg, Revision Dependent
Firmware:
FW Placeholder - Firmware Must Be Selected Separately
Material Number:
R911325247
Product Family:
IndraDrive Cs HCS01
Product Type:
Single-axis Compact Converter With Integrated Control Section
Maximum Current:
18 A
Continuous Current:
7 A
Mains Input:
3 AC 200 To 500 V, 50 To 60 Hz
Control Section Class:
BASIC
Communication:
ET MultiEthernet
Encoder Interface:
EC Multi-encoder Interface
Safety Configuration:
NN - Not Equipped
Second Optional Interface:
NN - Not Equipped
Cooling:
Internal Air Cooling With Integrated Blower
Protection Rating:
IP20
Reference Power Without Choke:
1.7 KW Continuous, 4.8 KW Maximum
Nominal Dimensions:
70 X 220 X 268 Mm, Width X Height X Depth
Reference Weight:
Approximately 2.10 Kg, Revision Dependent
Firmware:
FW Placeholder - Firmware Must Be Selected Separately
Description
HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW 18A Ethernet Drive

The HCS01.1E-W0018-A-03-B-ET-EC-NN-NN-NN-FW is the general-purpose 18 A BASIC configuration in the compact HCS01 range. The power stage and control electronics are integrated in one drive, while ET MultiEthernet and EC multi-encoder hardware support flexible connection to the surrounding automation system and motor feedback.

Unlike the L4 and S4 versions, this order code has NN in the safety position and therefore must not be marketed as containing a drive-integrated safety option. It is best positioned as an exact spare for machines already using the same suffix, with the firmware, motor parameters and network protocol confirmed from the original project or nameplate data.

Key Features

· 18 A maximum-current class with 7 A continuous-current reference

· BASIC integrated control section for economical single-axis applications

· ET MultiEthernet communication hardware

· EC multi-encoder interface for supported feedback systems

· No drive-integrated safety option in this exact NN configuration

· Compact IP20 housing with internal blower cooling

Typical Applications

· General automation axes

· Conveyor and indexing systems

· Handling equipment

· Exact replacement for R911325247 installations

Compatibility and Selection Note

Match the entire model string, including the three NN option fields. An L4, S4 or other safety-equipped drive may have different wiring, commissioning and approval requirements even when the current class is also W0018.

Frequently Asked Questions

Q1 Does this exact model include STO or Safe Motion?

No drive-integrated safety option is identified in this order code. The safety field is NN. Use the machine's external safety architecture or select the exact specified safety variant.

Q2 Which communication interface is built in?

The ET code identifies MultiEthernet hardware. Confirm the protocol selected by the firmware and the original machine project.

Q3 Is R911325247 the same as every HCS01 W0018 drive?

No. R911325247 maps to this exact BASIC, ET, EC and NN option combination. Other W0018 material numbers can differ in safety or optional interfaces.

Q4 Can the existing firmware be copied from the removed drive?

Parameter and firmware transfer may be possible in a controlled service process, but version compatibility and machine backups must be checked before replacement.

Q5 What is required for cabinet installation?

Provide suitable IP20 cabinet protection, grounding, ventilation clearance and clean cooling air. Follow the applicable project planning manual.

Q6 Why should the full suffix be included in the inquiry?

The suffix identifies control performance, communication, encoder and safety hardware. Supplying only HCS01.1E-W0018 can lead to an incompatible quotation.

Tags:

Send your inquiry
Please send us your request and we will reply to you as soon as possible.