Product Details
Place of Origin: GERMANY
Brand Name: Rexroth
Model Number: HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW
Payment & Shipping Terms
Material Number: |
R911326040 |
Product Family: |
IndraDrive Cs HCS01 |
Product Type: |
Single-axis Compact Converter With Integrated Control Section |
Maximum Current: |
9 A |
Continuous Current: |
3 A |
Mains Input: |
02 - 1 AC Or 3 AC 110 To 230 V, Application Dependent |
Mains Frequency: |
50 To 60 Hz |
Control Section Class: |
BASIC |
Communication: |
ET MultiEthernet |
Encoder Interface: |
EC Multi-encoder Interface |
Safety Configuration: |
NN - Not Equipped |
Cooling: |
Internal Air Cooling With Integrated Blower |
Protection Rating: |
IP20 |
Reference Power Without Choke: |
0.46 KW Continuous, 1.38 KW Maximum |
Nominal Dimensions: |
50 X 220 X 215 Mm, Width X Height X Depth |
Reference Weight: |
Approximately 1.10 Kg |
Firmware: |
FW Placeholder - Firmware Must Be Selected Separately |
Material Number: |
R911326040 |
Product Family: |
IndraDrive Cs HCS01 |
Product Type: |
Single-axis Compact Converter With Integrated Control Section |
Maximum Current: |
9 A |
Continuous Current: |
3 A |
Mains Input: |
02 - 1 AC Or 3 AC 110 To 230 V, Application Dependent |
Mains Frequency: |
50 To 60 Hz |
Control Section Class: |
BASIC |
Communication: |
ET MultiEthernet |
Encoder Interface: |
EC Multi-encoder Interface |
Safety Configuration: |
NN - Not Equipped |
Cooling: |
Internal Air Cooling With Integrated Blower |
Protection Rating: |
IP20 |
Reference Power Without Choke: |
0.46 KW Continuous, 1.38 KW Maximum |
Nominal Dimensions: |
50 X 220 X 215 Mm, Width X Height X Depth |
Reference Weight: |
Approximately 1.10 Kg |
Firmware: |
FW Placeholder - Firmware Must Be Selected Separately |
The HCS01.1E-W0009-A-02-B-ET-EC-NN-NN-NN-FW is a compact 9 A converter for lower-voltage single-axis systems. It combines BASIC control, MultiEthernet connectivity and a multi-encoder feedback interface, while retaining an NN safety configuration for machines that do not specify a drive-integrated safety option.
The 02 mains-voltage class is the most important electrical distinction from the 03-class HCS01 models in this batch. It is suited to 110 to 230 V-class supply arrangements, subject to the official project-planning limits. The exact motor voltage, phase arrangement, mains components and firmware must be confirmed before installation.
· 9 A maximum and 3 A continuous-current reference
· Lower 02 mains-voltage class
· BASIC integrated control section
· ET MultiEthernet communication
· EC multi-encoder interface
· No drive-integrated safety option in the exact NN code
· 230 V-class compact machinery
· Small conveyors and indexers
· Laboratory and assembly automation
· Exact spare for R911326040 systems
Use the complete model and R911326040. The A-02 voltage class, NN safety field and firmware must match the installed system. Do not choose a W0009 L4 model only because the current rating is the same.
Q1 How is this different from the W0009 L4 model?
The power and voltage classes are similar, but this version has no L4 safety option. The L4 model includes STO and Safe Brake Control.
Q2 Can the drive be supplied from single-phase mains?
The 02 class supports lower-voltage arrangements that can include single-phase operation. Validate the exact connection, loading and external components using the project planning data.
Q3 Is this a complete drive or a power section only?
HCS01 integrates its control and power sections. Firmware still has to be selected or confirmed separately.
Q4 What does EC provide?
EC identifies the multi-encoder feedback interface. Actual compatibility depends on the encoder, cable and firmware.
Q5 Can it replace an HCS02 W0012?
No direct substitution should be assumed. HCS01 and HCS02 have different architectures, dimensions, control arrangements and project requirements.
Q6 What should be checked after delivery?
Verify the type code, R911326040, voltage class, firmware label, connector condition and production revision before commissioning.
Tags: