Verification: dd9dbffd7e34a82b
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
english
quote
Products
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
Home /

Products

B&R X20SO2110 2-Channel 0.5A Type A Safe Output Module

Product Details

Place of Origin: Austria

Brand Name: B&R

Model Number: X20SO2110

Payment & Shipping Terms

Get Best Price
Contact Now
Specifications
Highlight:
Product Family:
X20 SafeIO
Module Type:
Safe Semiconductor Digital Output Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Outputs:
2 Type A Digital Outputs
Output Circuit:
FET; One Positive And One Negative Switching Path Per Channel
Nominal Voltage:
24 VDC
Nominal Output Current:
0.5 A Per Channel; 1 A Total
Current Monitoring:
Yes, Including Open-circuit Detection
OSSD Test Pulse:
Less Than 500 µs
Leakage Current Off:
Less Than 10 µA
Electrical Isolation:
Channels Isolated From Bus
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Product Family:
X20 SafeIO
Module Type:
Safe Semiconductor Digital Output Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Outputs:
2 Type A Digital Outputs
Output Circuit:
FET; One Positive And One Negative Switching Path Per Channel
Nominal Voltage:
24 VDC
Nominal Output Current:
0.5 A Per Channel; 1 A Total
Current Monitoring:
Yes, Including Open-circuit Detection
OSSD Test Pulse:
Less Than 500 µs
Leakage Current Off:
Less Than 10 µA
Electrical Isolation:
Channels Isolated From Bus
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Description
B&R X20SO2110 2-Channel 0.5A Type A Safe Output Module

The B&R X20SO2110 provides two 0.5 A type A safe semiconductor outputs for floating 24 VDC actuators such as contactors, relays and valves. Each channel uses positive and negative switching paths, allowing the actuator connection to be safely interrupted under defined fault conditions.

This model is the lower-current counterpart to X20SO2120. Both have two type A outputs and current monitoring, but X20SO2110 is rated at 0.5 A per channel and 1 A total. It is a practical choice when diagnostic current monitoring is required without the higher 2 A channel capacity.

Open-circuit detection, integrated output protection and restart protection after network faults support maintainable safety-output circuits.

Key Features

  • Two type A safe semiconductor outputs
  • 0.5 A nominal current per channel
  • Positive and negative switching for floating loads
  • Current monitoring and open-circuit detection
  • OSSD test pulse shorter than 500 µs
  • Integrated output protection and status diagnostics

Typical Applications

  • Safety contactor and relay control
  • Pneumatic valve shutdown circuits
  • Guard-lock release circuits within rated limits
  • Packaging and assembly machinery
  • X20SO2110 replacement and repair projects

Safety and Compatibility Note

The X20SO2110 can be used in safety-related applications up to PL e or SIL 3 only when the complete safety function is correctly engineered, configured, commissioned and validated. The achievable safety level depends on the full sensor, logic, communication, wiring and actuator chain. Check the exact hardware revision, firmware, Automation Studio hardware definition and SafeDESIGNER project before replacing an installed module.

FAQ

Q: What is the difference between X20SO2110 and X20SO2120?

A: X20SO2110 is rated at 0.5 A per output, while X20SO2120 is rated at 2 A per output.

Q: What does type A output mean?

A: The channel uses positive and negative switching paths and is intended for floating actuators without an external reference potential.

Q: Does the module detect an open load?

A: Yes. It uses internal current measurement for open-circuit monitoring.

Q: What accessories are required?

A: One X20BM33 or X20BM36 bus module and one X20TB52 safety-keyed terminal block are required.

Q: Can it switch any 24 VDC load?

A: No. Confirm steady-state current, inrush current, inductive energy, capacitance and the approved output application before selection.

Q: Does the 0.5 A rating guarantee SIL 3?

A: No. The output module is one part of a complete safety function that must be engineered and validated.

Tags:

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send