Verification: dd9dbffd7e34a82b
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
english
quote
Products
Dengfeng (Zhaoqing) Trading Co., Ltd
Products
Home /

Products

B&R X20SO2120 2-Channel 2A Type A Safe Output Module

Product Details

Place of Origin: Austria

Brand Name: B&R

Model Number: X20SO2120

Payment & Shipping Terms

Get Best Price
Contact Now
Specifications
Highlight:
Product Family:
X20 SafeIO
Module Type:
High-current Safe Semiconductor Output Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Outputs:
2 Type A Digital Outputs
Output Circuit:
FET; One Positive And One Negative Switching Path Per Channel
Nominal Voltage:
24 VDC
Nominal Output Current:
2 A Per Channel; 4 A Total
Current Monitoring:
Yes, Including Open-circuit Detection
OSSD Test Pulse:
Less Than 500 µs
Bus / Internal I/O Power:
0.25 W / 0.98 W
Electrical Isolation:
Channels Isolated From Bus
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Product Family:
X20 SafeIO
Module Type:
High-current Safe Semiconductor Output Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Outputs:
2 Type A Digital Outputs
Output Circuit:
FET; One Positive And One Negative Switching Path Per Channel
Nominal Voltage:
24 VDC
Nominal Output Current:
2 A Per Channel; 4 A Total
Current Monitoring:
Yes, Including Open-circuit Detection
OSSD Test Pulse:
Less Than 500 µs
Bus / Internal I/O Power:
0.25 W / 0.98 W
Electrical Isolation:
Channels Isolated From Bus
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Description
B&R X20SO2120 2-Channel 2A Type A Safe Output Module

The B&R X20SO2120 is a two-channel type A safe output module rated at 2 A per channel and 4 A total. It is intended for floating 24 VDC actuators that demand more current than the X20SO2110 can provide while still requiring output monitoring and integrated semiconductor protection.

Compared with X20SO2110, the channel count and type A architecture are unchanged, but the nominal current rises from 0.5 A to 2 A per channel. This makes X20SO2120 suitable for larger contactors, valve groups or other approved safety loads with higher continuous-current requirements.

The final load selection must still consider inrush current, output capacitance and inductive switching behavior, not only the 2 A steady-state rating.

Key Features

  • Two 2 A type A safe outputs
  • Four-amp total nominal output capacity
  • Positive and negative switching for floating actuators
  • Current monitoring and open-circuit detection
  • OSSD test pulse shorter than 500 µs
  • Integrated protection for industrial safety loads

Typical Applications

  • Higher-current safety contactors
  • Safety shutoff valves and valve manifolds
  • Machine zones with two independent high-current loads
  • Packaging, converting and processing equipment
  • Replacement of X20SO2120 modules

Safety and Compatibility Note

The X20SO2120 can be used in safety-related applications up to PL e or SIL 3 only when the complete safety function is correctly engineered, configured, commissioned and validated. The achievable safety level depends on the full sensor, logic, communication, wiring and actuator chain. Check the exact hardware revision, firmware, Automation Studio hardware definition and SafeDESIGNER project before replacing an installed module.

FAQ

Q: How much output current does X20SO2120 provide?

A: It is rated at 2 A per channel with a total nominal current of 4 A.

Q: How is it different from X20SO2110?

A: X20SO2120 offers four times the nominal current per channel: 2 A instead of 0.5 A.

Q: Is it suitable for loads tied to a reference potential?

A: Type A outputs are intended for floating actuators. Reference-potential loads may require an appropriate type B output architecture.

Q: Does it monitor the load current?

A: Yes. Current monitoring is used for open-circuit diagnostics.

Q: Which base and terminal are required?

A: Use X20BM33 or X20BM36 with one X20TB52 terminal block.

Q: Can I select it only by continuous current?

A: No. Check inrush current, inductive energy, capacitance, wiring and the safety response requirements.

Tags:

Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send