B&R X20SI4100 4-Channel Safe Input with Pulse Outputs

Product Details

Place of Origin: Austria

Brand Name: B&R

Model Number: X20SI4100

Payment & Shipping Terms

Get Best Price
Contact Now
Specifications
Highlight:
Product Family:
X20 SafeIO
Module Type:
Safe Digital Input Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Inputs:
4 Type A Digital Inputs
Input Circuit:
Sink, EN 61131-2 Type 1
Pulse Outputs:
4 Push-pull Diagnostic Pulse Outputs
Nominal Voltage:
24 VDC
Input Filter:
Hardware ≤150 µs; Software Configurable From 0 To 500 Ms
Switching Thresholds:
Low <5 VDC; High >15 VDC
Electrical Isolation:
Channels Isolated From Bus; No Channel-to-channel Isolation
Bus / Internal I/O Power:
0.32 W / 1.25 W
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Product Family:
X20 SafeIO
Module Type:
Safe Digital Input Module
Safety Application:
Up To Cat. 4 / PL E And SIL 3 In A Validated System
Safe Inputs:
4 Type A Digital Inputs
Input Circuit:
Sink, EN 61131-2 Type 1
Pulse Outputs:
4 Push-pull Diagnostic Pulse Outputs
Nominal Voltage:
24 VDC
Input Filter:
Hardware ≤150 µs; Software Configurable From 0 To 500 Ms
Switching Thresholds:
Low <5 VDC; High >15 VDC
Electrical Isolation:
Channels Isolated From Bus; No Channel-to-channel Isolation
Bus / Internal I/O Power:
0.32 W / 1.25 W
Operating Temperature:
0 To 60°C Horizontal; 0 To 50°C Vertical
Protection Rating:
IP20
Module Pitch:
25 Mm
Required Bus Module:
X20BM33 Or X20BM36
Required Terminal Block:
1 × X20TB52 Safety-keyed Terminal Block
Description
B&R X20SI4100 4-Channel Safe Input with Pulse Outputs

The B&R X20SI4100 provides four type A safe digital inputs and four pulse outputs for monitoring emergency-stop contacts, safety switches and other 24 VDC safety devices. Individually configurable software filters allow the switch-on and switch-off behavior of each input to be adapted to the application.

Unlike the single-width X20SI4110, the X20SI4100 uses the conventional 25 mm SafeIO format. This makes it especially relevant for direct replacement in established machines whose wiring, bus module and cabinet layout were designed around the original double-width module.

The diagnostic pulse outputs help detect wiring faults when used with suitable potential-free contacts. Pulse-output current and other details can vary by hardware revision, so the exact revision must be checked during replacement engineering.

Key Features

  • Four type A safe digital inputs
  • Four pulse outputs for sensor-line diagnostics
  • Configurable software filter for every input channel
  • 24 VDC sink inputs with channel-to-bus isolation
  • Status diagnostics through LEDs and software
  • Designed for X20BM33/X20BM36 and X20TB52 accessories

Typical Applications

  • Emergency-stop and safety-door monitoring
  • Two-channel light curtain and interlock signals
  • Packaging and assembly machines
  • Process equipment with distributed safety inputs
  • Replacement of installed X20SI4100 modules

Safety and Compatibility Note

The X20SI4100 can be used in safety-related applications up to PL e or SIL 3 only when the complete safety function is correctly engineered, configured, commissioned and validated. The achievable safety level depends on the full sensor, logic, communication, wiring and actuator chain. Check the exact hardware revision, firmware, Automation Studio hardware definition and SafeDESIGNER project before replacing an installed module.

FAQ

Q: What is the difference between X20SI4100 and X20SI4110?

A: Both provide four safe inputs and four pulse outputs. X20SI4100 has a 25 mm pitch, while X20SI4110 is a 12.5 mm single-width module.

Q: What are the pulse outputs used for?

A: They can provide test pulses for detecting cross-circuits or wiring faults when used with suitable safety contacts and approved wiring.

Q: Can the input filter be adjusted?

A: Yes. The software input filter is configurable per channel from 0 to 500 ms.

Q: Which accessories are required?

A: Use one X20BM33 or X20BM36 safety bus module and one X20TB52 safety-keyed terminal block.

Q: Can X20SI4100 operate without SafeLOGIC?

A: No. It is a SafeIO module and must be integrated into a correctly configured openSAFETY system.

Q: Can any hardware revision be exchanged without checking the project?

A: No. Confirm the hardware revision, firmware, Automation Studio definition, pulse-output data and validated safety configuration before replacement.

Tags: